Precast Concrete Pipe

Various Precast Concrete Pipe Product

Archive for December, 2009

RINKER O-RING SANITARY SEWER REINFORCED PIPE

Posted by irwanbee On December - 15 - 2009

Rinker O-Ring Sanitary Sewer Reinforced PipeRinker Materials manufactures a finish line of customary as well as specifically written reinforced petrify O-Ring siren for assorted spotless cesspool applications. This would embody both sobriety as well as low-head vigour applications.

Uses/Applications
Sanitary Sewer – Gravity & Low-Head Pressure

Specifications
ASTM C 76 Standard Specification for Reinforced Concrete Culvert, Storm Drain, as well as Sewer Pipe
ASTM C 361 Standard Specification for Reinforced Concrete Low-Head Pressure Pipe
ASTM C 655 Standard Specification for Reinforced Concrete D-Load Culvert, Storm Drain, as well as Sewer Pipe
AASHTO M 170 Standard Specification for Reinforced Concrete Culvert, Storm Drain, as well as Sewer Pipe
AWWA C 302 Reinforced Concrete Pressure Pipe, Noncylinder Type

Additional Information
The siren is made in all a customary sizes as well as is written to encounter or surpass germane ASTM/AASHTO/AWWA standards as well as internal requirements.

Incoming search terms for the article:

SHERMAN-DIXIE PRECAST CONCRETE PIPE

Posted by irwanbee On December - 10 - 2009

Sherman-Dixie Precast Concrete PipeReinforced Concrete Pipe is a many permanent as well as careful of all piping products. Recommended for installations where:

* Low, assuage or serious cover and/or live bucket conditions exist.
* Structural disaster competence discredit hold up or property. (Reinforced pipe, even after idealisation failure, retains a figure as well as will not collapse.)

Sizes
Reinforced Concrete Pipe is straightforwardly accessible in turn diameters of 12″ by 144″ as well as elliptical sizes homogeneous to 18″ to 60″ pipe.

Description
Precast petrify siren is a customary by that all drainage siren materials have been measured. Despite rival hype — constructional integrity, proven durability, as well as one after another “least risk” designs have been a vital reasons because pattern engineers go on to select petrify siren over stretchable siren materials for “sustainable design” of their drainage projects.

Available Specifications
* ASTM C76/AASHTO M170 – Reinforced Concrete Culvert, Storm Drain as well as Sewer Pipe
* ASTM C361 – Reinforced Concrete Low Head Pressure Pipe
* ASTM C655 – Reinforced Concrete D-Load Culvert, Storm Drain as well as Sewer Pipe
* ASTM C443/AASHTO M198 – Joints for Circular Concrete Sewer
* ASTM C-507 – Reinforced Concrete Elliptical Culvert, Storm Drain as well as Sewer Pipe

Application
Reinforced Concrete Pipe is constructed for a following:
* Sanitary Sewers
* Storm Sewers
* Culverts
* Detention Systems
* Low Pressure Force Mains

Joints
Full operation of choices to fit plan mandate from “soil-tight” to “water tight” seals, written to surpass germane ASTM as well as AASHTO standards to Bell as well as Spigot, O-Ring, Single Offset as well as Straight Wall designs.

Quality
All precast petrify siren is made according to difficult inhabitant peculiarity carry out standards of a American Concrete Pipe Association (ACPA).

Incoming search terms for the article:

RINKER MICROTUNNELING (JACKING) PIPE

Posted by irwanbee On December - 7 - 2009

Rinker Microtunneling (Jacking) PipeRinker Materials is an attention personality in a pattern as well as manufacturer of Reinforced Concrete Microtunneling Pipe.

Uses/Applications
Storm Drain, Culverts, Storm Sewers & Sanitary Sewers

Specifications
All microtunneling/jacking siren is made to encounter a compulsory plan specifications; be it for charge or spotless applications

Additional Information
Rinker Pipe provides a accumulation of specifically written microtunneling/jacking joints to encounter a far-reaching operation of plan mandate for possibly charge or spotless applications.